        CMS-5100

        Pulse Oximeter with NIBP

      Specification

  • 2.8” Height brightness TFT LCD display

  • High-brightness LED display of NIBP, SpO2, and Pulse rate

  • Visual and Audio alarms, Adjustable Memory: Built-in flash memory Audio volume adjustable

  • Build-in rechargeable Li-Polimer

  • NIBP

  • Mode: Manual/Auto/Continuous

  • Dimensions (LxWxH): 190x160x244 (mm) Net Weight: 1.5Kg

pulse oximeter hand held

      Flight 65

     Pulse Oximeter (Hand Held)

     Specification 

  • Small in volume, light in weight, and convenient in carrying.

  • Operation of the products is simple, with low power consumption.

  • Operation menu for the function setting.

  • SpO2 value display.

  • Pulse rate value display, bar graph display.

  • Screen brightness can be changed. 

  • Pulse rate sound indication.

  • With clock function.

  • Battery capacity Indication

  • Real data can be transmitted to computers.
    Low voltage indication: Low-voltage indication appears before working abnormally due to 
    low-voltage and with an alarm function

     

ecg machine 12 chennel

      ECG-12 Channel

        ECG Machine 12 Channel

     Specification

  • Sync collection for 12-lead ECG, adopt digital signal processing technology and get high-quality ECG waveform via power frequency filter,  baseline filter, and EMG filter of ECG signal.

  • Display of 3/6/12-lead ECG, Print mode, sensitivity, paper speed, filter state, etc. on one Screen, convenient for contrastively diagnosing.

  • Paper speed: 5mm/s, 6.25mm/s, 10mm/s, 12.5mm/s, 50mm/s.

  • Built-in memory stores up to 1000 cases, convenient for case review and statistics.

ecg machine three channel

      ECG-Three Channel

      ECG Machine Tree Channel

     Specification

  • 3.5” TFT Color LCD display shows the working status and ECG waveform. Check the waveform Before Printing to save record paper.                 

  • 12 Leads ECG simultaneous acquisition. Digital signal processor, to get higher quality ECG waveforms through the AC filter, Baseline filter, and EMG filter of the ECG signals.

  • Simultaneous display of 3/6/12 leads ECG waveform, and the state of printing mode, Sensitivity, Speed, filter, etc., to be easy for interpretation.

CMS 800G1

     Flight-800     

     Fetal Monitor

     Specification

  • Light dexterous appearance, tops horizontally and walls Can be hoisted

  • 8.0” Screen color LCD display, rotatable screen to 60 Display of the patient data and curve clearly

  • FHR 120 BPM - 160 BPM Normal range label Manual records fetal movement.

  • Sound and color alarm for high and low fetal heart rate. Continuous 24-hour real time monitoring function

  • Continuous 12-hour patient curve and data storage, playback, and print with Picture freeze function.

  • Optional English Interface.

ambulatory blood pressure

       Flight-50

       Ambulatory Blood Pressure

      Monitor   

        Specification

  • Compact and portable, user-friend interface, easy to use

  • Patients range: adult pediatric, neonate

  • 24 hours ambulatory NIBP monitoring function, up to 350 groups of ambulatory NIBP data can be recorded once.

  • High-definition color TFT display, alarm, error message, and time.

  • parameter alarm dispose of function is optional.

  • Supply two kinds of units: mmHg/kpa. 

  • Communicate with PC, PC software can achieve data review, measured results analysis, view of trend graphs, report printing, and other functions

  • A perfect combination of automatic and manual measurement methods up to 300 groups of data can be recorded once by manual measure.

     

Automatic AED

      AED-7000AED                                    (Automatic External Defibrillator)  

  • Specification

  • AED 7000 (Automatic External Defibrillator) is a defibrillator device, which is safe, portable, and easy to use. It can be applied in families and the public to give first aid to sudden death symptoms. Combined with the advanced ECG analytical technique from M&B company, the defibrillator can analyze the patient's ECG, make a judgment for the patient's cardiac condition and indicate whether the defibrillation is needed and the defibrillation strength. It can not only enhance the success rate of defibrillation. it also reduces the injury of defibrillation to the heart to the utmost extent. There is a Low Requirement for the operation to use the device. The defibrillator will guide the operator to carry out defibrillation treatment via voice prompt step by step and give a safety alert if the occasion arises. It can carry early defibrillation treatment effectively and protect the operator farthest, being very applicable to emergency treatment for sudden cardiac death patients in family and public places.

  • The AED 7000 Automatic External Defibrillator delivers the defibrillation shock through two self-adhesive, Pre-gelled, low-impedance electrodes, and defibrillator pads.

spirometer

      SP-10

        Spirometer Hand Held

        Specification

  • Wireless transmission (be applicable for SP10W)

  • Display trend curve

  • Scaling (calibration)

  • Information prompts when volume or flow goes beyond the limits

  • Automatic power off when there is no operation in one minute

  • Rechargeable lithium battery with charging tips

  • Battery power display

  • Performance:

  • Display mode: 1.8" color LCD

  • Display resolution: 160 x 128

  • Volume range: 0-10 L

  • Volume accuracy: ±3% or 0.05 L (whichever is greater)

  • Flow range: 1 L/S - 16 L/S

  • Flow accuracy: ±10% or ±0.3 L/s (whichever is greater)

  • Power supply: 3.7 V DC rechargeable lithium battery

  • Safety classification: internally powered equipment, type BF applied part

phototheraphy

      BT-400                                                                                phototherapy

      Specification​

  • Light Source-Blue LEDs

  • Wavelength = Peak between 450-475mm.

  • Intensity = 20-100nW / cm2/nm at 40cm.

  • Variation in intensity over 6 hours = +10(within illumination area).

  • Effective surface area = 40x20cm
    Function

  • Intensity control Low intensity:20-70uW/cm2/nm+10% High intensity: 40-100uW/cm/nm+10%
    30min- 999 hours 30min.
    Features

  • 20,000-hour operating time.

  • High intensity with efficient treatment.

  • Operating & total using time display.

  • Timer, 2-level adjustable intensity.

  • Lightweight and compact size.

aed defibllator

       ACES

       Defibrillator    

       Specification

  • Display:- 7" color TFT

  • Display area :- 150mm x 90mm

  • Dimensions :- H280 x W 330 x D220 mm (Max) without Paddle 

  • Weight:- Approx . 6 kgs.

  • Unit ON-OFF:- By front panel keyboard , Encoder

  • Operation:- User adjustable high & low limit, Audible and visual alarming

  • Alarm:- 24 hrs Graphical and tabular trend of ECG, SPO2, NIBP ETCO2 

  • Charge Discharge Control:- Charge and shock button on the front panel and paddles. 

  • ETCO2 (Optional)

  • Parameter :- ETCO2 RR

  • Adapter:- Adult Pediatric, Neonate 

  • Measurement Mode :- Mainstream & Sidestream 

  • ETCO2 Range:- 0-100 mmHg

  • Accuracy :- +/- 2 mmHg

  • Respiration Range:- 0-120 bpm

infusion pump

     IP-01

       Infusion Pump

     Specification

  • Infusion Rate : 0.1ml/h---1200ml/h (1ml/h step)

  • Rate Accuracy: within 5% (aGer correct calibration)

  • Purge Rate : 100ml/h---1200ml/h (can be calibrated)

  • Alarm: End of injection, Occlusion, Door Open, Bubbles in a tube.

  • Alarm: Wrong setting, Low Battery, AC Power Pulled Out, etc.

  • Power Source: 100V---240V 50/60Hz;4 hours internal battery backup.

  • KVO speed : 1ml/h---5ml/h (1ml/h step)

  • Power Consumption: 18VA

syringe pump

     SP-03

       Syringe Pump

     Specification

  • Screen Size: 2.8 inches

  • Dimension : 278mm x 145mm x 106mm Weight : 1.5 Kg

  • Power supply : 100V-240V 50/60Hz

  • Power Consumption : <55VA Disposable Syringes” Maximum Flow Rate: 1800 ( ml/h )1800 ( ml/h )

  • Syringe Requirement: Refer to “Section 11 Notes on Disposable Syringes”

oxygen concentrator

     OC-101

       Oxygen Concentrator 5 Litre 

      Single Flow

     Specification

  • Flow Rate = 0-5L/min 

  • Purity = 93+3% 

  • Outlet Pressure (Mpa) = 0.04-0.07

  • Sound Level = 50db

  • Power = AC230V, 50Hz (AC220V/110+10%,50/60+1Hz are available)`

  • Power Consumption = 480W

  • LCD Display = Switch times, Operating pressure, Present working time, Accumulating time, Presetting time from 10mms to 40hours

  • Alarm = Power failure Alarm, High & Low pressure alarm

  • Net Weight = 25Kgs

  • Size(mm) = 365 x 375 x 600

ventilators

       Airlog 1

       ICU Ventilator

  • Specification

  • 12-inch large screen with desirable color schemes

  • Easy to operate

  • Support adult and pediatric ventilation mode

  • Intelligence operating system

  • Air compressor support (optional)

  • Multi-mode Ventilation function (VCV, SIMV, PSV, PCV, CPAP, Manual SIng)

  • Specification

  • Dimensions = 45*55*140cm

  • Weight           = 65kg

  • Casters          =  Central brake with loc

  • Screen            = 12 inch  

  • Display           = Color LCD

  • Display graphics  = Waveforms of P-T, F-T, V-T

  • Loops              = P-V, F-V(optional)

  • Screen  control = NEC no dead spot at any angle Environmental Conditions

  • Oprating Temp = 5 C~ 40 C

  • Strong Temp = -10C ~ +40C

  • Humidity = <80%

  • Atmosphere Pressure = 960hpa ~ 1040hpa

trolley model suction

      SU-103

       Trolley Model Suction

       Specification

  • Voltage = AC 220 V/50Hz

  • Max. Negative Pressure = 0.09MPa /

  • Value = 680mmHg

  • Pumping Rate = 20 L/min

  • Reservoir Volume = 2500ml x 2 jars

  • Input Power = 150 VA + 15%

  • Noise = 60dB(A)

        BT-410

        Head Lamp   

        Specification

  • Material: ABS

  • Weight: 74 g

  • Product size: 60 x 40 x 35 mm

  • Lumen: 80 lm

  • Battery type: Built-in 1200 mAh Polymer Lithium battery

  • Working time: 5 to 20 hours

  • Charge time: 2.5 hours

        ND-105

        Fetal Doppler    

        Specification

  • Work Frequency: 2.0 MHZ +10%

  • Ultrasonic output power: lob<10mW/cm2

  • Overall sensitivity:>90dB (integrate sensitivity 200mm away from the surface of the probe)

  • While measuring integrated sensitivity using the doppler frequency (300+50)Hz

  • Reflecting target speed: 10cm/s-40cm/s

  • FHR measuring range: No narrow than 50bpm-240bpm(+bpm). (Beat a=pr minute) FHR accuracy - 2bpm

  • Battery type recommended two pieces of 1.5 V DC battery (Size AA LR6) atmospheric pressure 86kpa-106kPa

  • Transport and strong environment temperature:- 10C-+40C humidity <80%

nisco india logo

Links

NISCO (INDIA) was established in the year 1982 and has since been engaged in the export of Medical Equipment, Hospital Equipment, Orthopaedic Implants & instruments, Laboratory equipment, and Scientific & Educational products worldwide. Your support has made us a "Government of India" recognized export house. Our goods have reached all continents from "The Americas" to "Europe" and beyond…